Kami adalah perusahaan spesialis di bidang System Pemadam Kebakaran, Alarm kebakaran, alarm keamanan, CCTV, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll Fire Protection System : Fire Alarm ( Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll)

Detail Notifier Fire Alarm Panel, Type: SFP 10 UDE

General The SFP-5UD is a five-zone FACP ( Fire Alarm Control Panel) and the SFP-10UD( E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/ download. Each of these FACPs is compatible with System Sensor’ s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “ freeze” signal when the ambient temperature falls below the detector rating. Additionally, both the SFP-5UD and SFP- 10UD are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs ( Notification Appliance Circuits) , three programmable Form-C relays ( factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The SFP-10UDE offers the same features as the SFP- 10UD but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see dn-60437. Features • Listed to UL Standard 864, 9th edition. • Built-in DACT ( Digital Alarm Communicator/ Transmitter) . • Style B ( Class B) IDC ( Initiating Device Circuit) – SFP-5UD - five IDCs. – SFP-10UD - ten IDCs. • Style Y ( Class B) NAC ( Notification Appliance Circuit) - special application power – SFP-5UD - four NACs. – SFP-10UD - four NACs. • Notification Appliances may be programmed as – Silence Inhibit. – Auto-Silence. – Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. – Selective Silence ( horn-strobe mute) . – Temporal or Steady Signal. – Silenceable or Nonsilenceable. • Optional N-CAC-5X Style Z ( Class A) Converter Module for NACs and IDCs ( 2 required for SFP-10UD) . • Form-C Relays for Alarm, Trouble and Supervisory - Contact Ratings 2.0 [email protected] 30 VDC or 30 VAC ( resistive) . • 3.0 A total system current for SFP-5UD. • 7.0 A total system current for SFP-10UD. • Optional Dress Panel DP-51050 ( red) • Optional Dress Panel DP-51050B ( black) . • Optional Trim Ring TR-CE/ -B for semi-flush mounting. • 24 volt operation. • Low AC voltage sense. • Alarm Verification. • PAS ( Positive Alarm Sequence) . • Automatic battery trickle charger. • Up to eight ANN-BUS annunciators: – Optional 8 zone Relay Module N-ANN-RLY. – Optional LED Annunciator Module N-ANN-LED, – Optional Remote LCD Annunciator N-ANN-80. – Optional Remote Printer Gateway N-ANN-S/ PG. – Optional LED Annunciator Driver N-ANN-I/ O. • Optional 4XTM module ( conventional reverse polarity/ city box transmitter) . PROGRAMMING AND SOFTWARE: • Can be programmed at the panel with no special software or additional equipment. • Programmable Make/ Break Ratio. • Upload/ Download ( local or remote) of program and data via integral DACT USER INTERFACE: • Built-in DACT ( Digital Alarm Communicator/ Transmitter) . • Integral 80-character LCD display with backlighting and keypad. • Real-time clock/ calendar with automatic daylight savings adjustments. • ANN-BUS for connection to remote annunciators. • Audible or silent walk test capabilities. • Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS • FIRE ALARM ( red) • SUPERVISORY ( yellow) • TROUBLE ( yellow) • AC POWER ( green) • ALARM SILENCED ( yellow) CONTROL BUTTONS • ACKNOWLEDGE • ALARM SILENCE • SYSTEM RESET ( lamp test) • DRILL

Tampilkan Lebih Banyak
metrotama modern
metrotama modern

METROTAMA MODERN

Anggota PREMIUM 5 Tahun
Griya Kebraon Selatan V/E-20, Karangpilang Surabaya Jawa Timur , Indonesia, SURABAYA
Indonesia 60222
SURABAYA
11 / 11 / 2019
Hubungi Kami

Detail Notifier Fire Alarm Panel, Type: SFP 10 UDE

General The SFP-5UD is a five-zone FACP ( Fire Alarm Control Panel) and the SFP-10UD( E) is a ten-zone FACP. These control panels provide reliable fire signaling protection for small to medium-sized commercial, industrial, and institutional buildings. Both panels include built-in communicators for Central Station Service and remote upload/ download. Each of these FACPs is compatible with System Sensor’ s microprocessor-based i3 series detectors. These conventional smoke detectors can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory “ freeze” signal when the ambient temperature falls below the detector rating. Additionally, both the SFP-5UD and SFP- 10UD are compatible with conventional input devices such as two- and four-wire smoke detectors, pull stations, waterflow devices, tamper switches, and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a complete listing of compatible devices. Outputs include four NACs ( Notification Appliance Circuits) , three programmable Form-C relays ( factory programmed for Alarm, Trouble, and Supervisory) and 24 VDC special application resettable and nonresettable power outputs. The FACPs supervise all wiring, AC voltage, battery level and telephone line integrity. Activation of a compatible smoke detector or any normallyopen fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and FACP alarm relay, and operate an optional module used to notify a remote station or initiate an auxiliary control function. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: The SFP-10UDE offers the same features as the SFP- 10UD but allows connection to 240 VAC. Unless otherwise specified, the information in this data sheet applies to both the 120 VAC and the 240 VAC versions of these panels. NOTE: For ULC-listed models, see dn-60437. Features • Listed to UL Standard 864, 9th edition. • Built-in DACT ( Digital Alarm Communicator/ Transmitter) . • Style B ( Class B) IDC ( Initiating Device Circuit) – SFP-5UD - five IDCs. – SFP-10UD - ten IDCs. • Style Y ( Class B) NAC ( Notification Appliance Circuit) - special application power – SFP-5UD - four NACs. – SFP-10UD - four NACs. • Notification Appliances may be programmed as – Silence Inhibit. – Auto-Silence. – Strobe Synchronization for System Sensor, Wheelock, Gentex, Faraday, or Amseco devices. – Selective Silence ( horn-strobe mute) . – Temporal or Steady Signal. – Silenceable or Nonsilenceable. • Optional N-CAC-5X Style Z ( Class A) Converter Module for NACs and IDCs ( 2 required for SFP-10UD) . • Form-C Relays for Alarm, Trouble and Supervisory - Contact Ratings 2.0 [email protected] 30 VDC or 30 VAC ( resistive) . • 3.0 A total system current for SFP-5UD. • 7.0 A total system current for SFP-10UD. • Optional Dress Panel DP-51050 ( red) • Optional Dress Panel DP-51050B ( black) . • Optional Trim Ring TR-CE/ -B for semi-flush mounting. • 24 volt operation. • Low AC voltage sense. • Alarm Verification. • PAS ( Positive Alarm Sequence) . • Automatic battery trickle charger. • Up to eight ANN-BUS annunciators: – Optional 8 zone Relay Module N-ANN-RLY. – Optional LED Annunciator Module N-ANN-LED, – Optional Remote LCD Annunciator N-ANN-80. – Optional Remote Printer Gateway N-ANN-S/ PG. – Optional LED Annunciator Driver N-ANN-I/ O. • Optional 4XTM module ( conventional reverse polarity/ city box transmitter) . PROGRAMMING AND SOFTWARE: • Can be programmed at the panel with no special software or additional equipment. • Programmable Make/ Break Ratio. • Upload/ Download ( local or remote) of program and data via integral DACT USER INTERFACE: • Built-in DACT ( Digital Alarm Communicator/ Transmitter) . • Integral 80-character LCD display with backlighting and keypad. • Real-time clock/ calendar with automatic daylight savings adjustments. • ANN-BUS for connection to remote annunciators. • Audible or silent walk test capabilities. • Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators LED INDICATORS • FIRE ALARM ( red) • SUPERVISORY ( yellow) • TROUBLE ( yellow) • AC POWER ( green) • ALARM SILENCED ( yellow) CONTROL BUTTONS • ACKNOWLEDGE • ALARM SILENCE • SYSTEM RESET ( lamp test) • DRILL

Tampilkan Lebih Banyak
Kontak Kami  
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus [email protected] !