Kami adalah perusahaan spesialis di bidang System Pemadam Kebakaran, Alarm kebakaran, alarm keamanan, CCTV, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll Fire Protection System : Fire Alarm ( Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll)

Detail Notifier Fire Alarm Panel, Type: NFS2 640

NFS2-640( E) Intelligent Addressable Fire Alarm System Contact: www.metrotama.com General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products 2 meet virtually every application requirement. Designed with modularity and for ease of system planning, the NFS2-640 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific “ E” at the end of the part number, “ NFS2-640” refers to models NFS2-640 and NFS2-640E; similarly, “ CPU2-640” refers to models CPU2-640 and CPU2-640E. Features • Listed to UL Standard 864, 9th edition. • One, expandable to two, isolated intelligent Signaling Line Circuit ( SLC) Style 4, 6 or 7. • Up to 159 detectors ( any mix of ion, photo, thermal, or multisensor) and 159 modules ( Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/ 636 per FACP or network node. • Standard 80-character display, 640-character large display, or display-less ( a node on a network) . • Network options: – High-speed network for up to 200 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA) . – Standard network for up to 103 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020) . Up to 54 nodes when DVC is used in network paging. • 6.0 amp switch mode power supply with four Class A/ B builtin Notification Appliance Circuits ( NAC) . Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 636-point DACT. • 80-character remote annunciators ( up to 32) . • EIA-485 annunciators, including custom graphics. • Printer interface ( 80-column and 40-column printers) . • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Presignal/ Positive Alarm Sequence ( PAS) . • Silence inhibit and Auto Silence timer options. • March time/ temporal/ California two-stage coding/ strobe synchronization. • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 – 200 amp hour batteries. • Non-alarm points for lower priority functions. • Remote ACK/ Signal Silence/ System Reset/ Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology ( SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. NCA-2 640-CHARACTER DISPLAY FEATURES: • Backlit, 640-character display. • Supports SCS Series smoke control system in both HVAC or FSCS modes ( not UL-Listed for FSCS) . • Printer and CRT EIA-232 ports. • EIA-485 annunciator and terminal mode ports. • Alarm, Trouble, Supervisory, and Security relays. FLASHSCAN® INTELLIGENT FEATURES: • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol ( U.S. Patent 5, 539, 389) . • Manual sensitivity adjustment — nine levels. • Pre-alarm ONYX intelligent sensing — nine levels. • Day/ Night automatic sensitivity adjustment. • Sensitivity windows: – Ion – 0.5 to 2.5% / foot obscuration. – Photo – 0.5 to 2.35% / foot obscuration. – Laser ( VIEW® ) – 0.02 to 2.0% / foot obscuration. – Acclimate Plus™ – 0.5 to 4.0% / foot obscuration. – IntelliQuad™ – 1.0 to 4.0% / foot obscuration. • Drift compensation ( U.S. Patent 5, 764, 142) . • Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/ Enable switch for this feature. Page 2 of 8 — dn-7111: c • 05/ 12/ 2009 • Multi-detector algorithm involves nearby detectors in alarm decision ( U.S. Patent 5, 627, 515) . • Automatic detector sensitivity testing ( NFPA-72 compliant) . • Maintenance alert ( two levels) . • Self-optimizing pre-alarm. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire ( smoke, heat, CO, and flame) . • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. • Six sensitivity levels. FSL-751 ( VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals ( U.S. Patent 5, 831, 524) . • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible. • Low-temperature warning signal at 40° F ± 5° F ( 4.44° C ± 2.77° C) . RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone ( three options) . • Delay timer and Discharge timers ( adjustable) . • Abort ( four options) . • Low-pressure CO2 listed. VOICE AND TELEPHONE FEATURES: • Up to eight channels of digital audio. • 50 and 75 watt digital amplifiers ( DAA series) . • Solid-state digital message generation. • Firefighter telephone option. • 30- to 120-watt high-efficiency amplifiers ( AA Series) . • Backup tone generator and amplifier option. • Multichannel voice transponder ( XPIQ) . HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY ( 6.0 A IN ALARM) : • 120 VAC ( NFS2-640) ; 240 VAC ( NFS2-640E) . • Displays battery current/ voltage on panel ( with display) .

Tampilkan Lebih Banyak
metrotama modern
metrotama modern

METROTAMA MODERN

PREMIUM GOLD 5 Tahun
Griya Kebraon Selatan V / E-20, Karangpilang, SURABAYA
Indonesia 60222
SURABAYA
27 / 08 / 2019
Hubungi Kami

Detail Notifier Fire Alarm Panel, Type: NFS2 640

NFS2-640( E) Intelligent Addressable Fire Alarm System Contact: www.metrotama.com General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products 2 meet virtually every application requirement. Designed with modularity and for ease of system planning, the NFS2-640 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. NOTE: Unless called out with a version-specific “ E” at the end of the part number, “ NFS2-640” refers to models NFS2-640 and NFS2-640E; similarly, “ CPU2-640” refers to models CPU2-640 and CPU2-640E. Features • Listed to UL Standard 864, 9th edition. • One, expandable to two, isolated intelligent Signaling Line Circuit ( SLC) Style 4, 6 or 7. • Up to 159 detectors ( any mix of ion, photo, thermal, or multisensor) and 159 modules ( Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/ 636 per FACP or network node. • Standard 80-character display, 640-character large display, or display-less ( a node on a network) . • Network options: – High-speed network for up to 200 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA) . – Standard network for up to 103 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020) . Up to 54 nodes when DVC is used in network paging. • 6.0 amp switch mode power supply with four Class A/ B builtin Notification Appliance Circuits ( NAC) . Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 636-point DACT. • 80-character remote annunciators ( up to 32) . • EIA-485 annunciators, including custom graphics. • Printer interface ( 80-column and 40-column printers) . • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Presignal/ Positive Alarm Sequence ( PAS) . • Silence inhibit and Auto Silence timer options. • March time/ temporal/ California two-stage coding/ strobe synchronization. • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 – 200 amp hour batteries. • Non-alarm points for lower priority functions. • Remote ACK/ Signal Silence/ System Reset/ Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology ( SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. NCA-2 640-CHARACTER DISPLAY FEATURES: • Backlit, 640-character display. • Supports SCS Series smoke control system in both HVAC or FSCS modes ( not UL-Listed for FSCS) . • Printer and CRT EIA-232 ports. • EIA-485 annunciator and terminal mode ports. • Alarm, Trouble, Supervisory, and Security relays. FLASHSCAN® INTELLIGENT FEATURES: • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol ( U.S. Patent 5, 539, 389) . • Manual sensitivity adjustment — nine levels. • Pre-alarm ONYX intelligent sensing — nine levels. • Day/ Night automatic sensitivity adjustment. • Sensitivity windows: – Ion – 0.5 to 2.5% / foot obscuration. – Photo – 0.5 to 2.35% / foot obscuration. – Laser ( VIEW® ) – 0.02 to 2.0% / foot obscuration. – Acclimate Plus™ – 0.5 to 4.0% / foot obscuration. – IntelliQuad™ – 1.0 to 4.0% / foot obscuration. • Drift compensation ( U.S. Patent 5, 764, 142) . • Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/ Enable switch for this feature. Page 2 of 8 — dn-7111: c • 05/ 12/ 2009 • Multi-detector algorithm involves nearby detectors in alarm decision ( U.S. Patent 5, 627, 515) . • Automatic detector sensitivity testing ( NFPA-72 compliant) . • Maintenance alert ( two levels) . • Self-optimizing pre-alarm. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire ( smoke, heat, CO, and flame) . • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. • Six sensitivity levels. FSL-751 ( VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals ( U.S. Patent 5, 831, 524) . • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible. • Low-temperature warning signal at 40° F ± 5° F ( 4.44° C ± 2.77° C) . RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone ( three options) . • Delay timer and Discharge timers ( adjustable) . • Abort ( four options) . • Low-pressure CO2 listed. VOICE AND TELEPHONE FEATURES: • Up to eight channels of digital audio. • 50 and 75 watt digital amplifiers ( DAA series) . • Solid-state digital message generation. • Firefighter telephone option. • 30- to 120-watt high-efficiency amplifiers ( AA Series) . • Backup tone generator and amplifier option. • Multichannel voice transponder ( XPIQ) . HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY ( 6.0 A IN ALARM) : • 120 VAC ( NFS2-640) ; 240 VAC ( NFS2-640E) . • Displays battery current/ voltage on panel ( with display) .