1
Hi, Guest!

Notifier Fire Alarm Panel, Type: NFS 320 ( E)

Update Terakhir
:
05 / 06 / 2019
Min. Pembelian
:
0 Unit
Kami adalah perusahaan spesialis di bidang System Pemadam Kebakaran, Alarm kebakaran, alarm keamanan, CCTV, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll Fire Protection System : Fire Alarm ( Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll)

Detail Notifier Fire Alarm Panel, Type: NFS 320 ( E)

NOTIFIER by HONEYWELL NFS-320( E) Intelligent Addressable Fire Alarm System By www.metrotama.com Intelligent Fire Alarm Control Panels General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. Designed with modularity and ease of system planning, the NFS-320 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet ( up to 48 zones/ points, order seperately) . The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless called out with a version-specific “ R” , “ C” or “ E” at the end of the part number, “ NFS-320” refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E; similarly, “ CPU-320” refers to the main circuit board for CPU-320, CPU-320C, and CPU-320E. Features • Listed to UL Standard 864, 9th edition. • One isolated intelligent Signaling Line Circuit ( SLC) Style 4, 6 or 7. • Up to 159 detectors ( any mix of ion, photo, thermal, or multisensor) and 159 modules ( Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) . 318 devices maximum. • Standard 80-character display. • Network options: – High-speed network for up to 200 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA) . – Standard network for up to 103 nodes ( NFS2-3030, NFS2- 640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS- 3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020) . Up to 54 nodes when DVC is used in network paging. • 6.0 amp power supply with four Class A/ B built-in Notification Appliance Circuits ( NAC) . Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 318-point DACT. • 80-character remote annunciators ( up to 32) . • EIA-485 annunciators, including custom graphics. • Printer interface ( 80-column and 40-column printers) . • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Presignal/ Positive Alarm Sequence ( PAS) . • Silence inhibit and Auto Silence timer options. • NAC coding functions: – March time. – Temporal. – California two-stage coding. – Canadian two-stage. – Strobe synchronization. • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 – 200 amp hour batteries • Non-alarm points for lower priority functions. • Remote ACK/ Signal Silence/ System Reset/ Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology ( SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. FLASHSCAN® INTELLIGENT FEATURES: • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol ( U.S. Patent 5, 539, 389) . • Manual sensitivity adjustment — nine levels. • Pre-alarm ONYX intelligent sensing — nine levels. • Day/ Night automatic sensitivity adjustment. • Sensitivity windows: – Ion – 0.5 to 2.5% / foot obscuration. – Photo – 0.5 to 2.35% / foot obscuration. – Laser ( VIEW® ) – 0.02 to 2.0% / foot obscuration. – Acclimate Plus™ – 0.5 to 4.0% / foot obscuration. – IntelliQuad – 1.0 to 4.0% / foot obscuration. • Drift compensation ( U.S. Patent 5, 764, 142) . • Degraded mode — in the unlikely event that the CPU-320 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU-320 NAC circuits and Page 2 of 6 — DN-7112: D1 • 10/ 06/ 2009 alarm relay. Each of the four built-in panel circuits includes a Disable/ Enable switch for this feature. • Multi-detector algorithm involves nearby detectors in alarm decision ( U.S. Patent 5, 627, 515) . • Automatic detector sensitivity testing ( NFPA-72 compliant) . • Maintenance alert ( two levels) . • Self-optimizing pre-alarm. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire ( smoke, heat, CO, and flame) . • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. • Six sensitivity levels. FSL-751 VIEW ( VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals ( U.S. Patent 5, 831, 524) . • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible. • Low-temperature warning signal at 40° F ± 5° F ( 4.44° C ± 2.77° C) . RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone ( three options) . • Delay timer and Discharge timers ( adjustable) . • Abort ( four options) . • Low-pressure CO2 listed. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY ( 6.0 A IN ALARM) : • 120 VAC ( NFS-320/ NFS-320C) ; 240 VAC ( NFS-320E) . • Displays battery current/ voltage on panel ( with display) . VOICE FEATURES: • Integrates with FireVoice-25/ 50 Series ( see DN-7004) . • Integrates via serial connection with FireVoice-25/ 50ZS Series ( see DN-7003) .

Tampilkan Lebih Banyak
metrotama modern
metrotama modern

METROTAMA MODERN

Anggota PREMIUM 5 Tahun
Griya Kebraon Selatan V/E-20, Karangpilang Surabaya Jawa Timur , Indonesia, SURABAYA
Indonesia 60222
SURABAYA
11 / 11 / 2019
Hubungi Kami

Detail Notifier Fire Alarm Panel, Type: NFS 320 ( E)

NOTIFIER by HONEYWELL NFS-320( E) Intelligent Addressable Fire Alarm System By www.metrotama.com Intelligent Fire Alarm Control Panels General The NFS-320 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER. In stand-alone or network configurations, ONYX Series products meet virtually every application requirement. Designed with modularity and ease of system planning, the NFS-320 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. For installations using NFS-320C, an optional ACM Series annunciator can be mounted in the same cabinet ( up to 48 zones/ points, order seperately) . The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. NOTE: Unless called out with a version-specific “ R” , “ C” or “ E” at the end of the part number, “ NFS-320” refers to models NFS-320, NFS-320R, NFS-320C, and NFS-320E; similarly, “ CPU-320” refers to the main circuit board for CPU-320, CPU-320C, and CPU-320E. Features • Listed to UL Standard 864, 9th edition. • One isolated intelligent Signaling Line Circuit ( SLC) Style 4, 6 or 7. • Up to 159 detectors ( any mix of ion, photo, thermal, or multisensor) and 159 modules ( Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) . 318 devices maximum. • Standard 80-character display. • Network options: – High-speed network for up to 200 nodes ( NFS2-3030, NFS2-640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS-3030, NFS-640, and NCA) . – Standard network for up to 103 nodes ( NFS2-3030, NFS2- 640, NFS-320( C) , NCA-2, DVC, ONYXWorks, NCS, NFS- 3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020) . Up to 54 nodes when DVC is used in network paging. • 6.0 amp power supply with four Class A/ B built-in Notification Appliance Circuits ( NAC) . Selectable System Sensor, Wheelock, or Gentex strobe synchronization. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware. • Autoprogramming and Walk Test reports. • Optional universal 318-point DACT. • 80-character remote annunciators ( up to 32) . • EIA-485 annunciators, including custom graphics. • Printer interface ( 80-column and 40-column printers) . • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file. • Alarm Verification selection per point, with tally. • Autoprogramming and Walk Test reports. • Presignal/ Positive Alarm Sequence ( PAS) . • Silence inhibit and Auto Silence timer options. • NAC coding functions: – March time. – Temporal. – California two-stage coding. – Canadian two-stage. – Strobe synchronization. • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate. • Full QWERTY keypad. • Battery charger supports 18 – 200 amp hour batteries • Non-alarm points for lower priority functions. • Remote ACK/ Signal Silence/ System Reset/ Drill via monitor modules. • Automatic time control functions, with holiday exceptions. • Surface Mount Technology ( SMT) electronics. • Extensive, built-in transient protection. • Powerful Boolean logic equations. FLASHSCAN® INTELLIGENT FEATURES: • Poll up to 318 devices in less than two seconds. • Activate up to 159 outputs in less than five seconds. • Multicolor LEDs blink device address during Walk Test. • Fully digital, high-precision protocol ( U.S. Patent 5, 539, 389) . • Manual sensitivity adjustment — nine levels. • Pre-alarm ONYX intelligent sensing — nine levels. • Day/ Night automatic sensitivity adjustment. • Sensitivity windows: – Ion – 0.5 to 2.5% / foot obscuration. – Photo – 0.5 to 2.35% / foot obscuration. – Laser ( VIEW® ) – 0.02 to 2.0% / foot obscuration. – Acclimate Plus™ – 0.5 to 4.0% / foot obscuration. – IntelliQuad – 1.0 to 4.0% / foot obscuration. • Drift compensation ( U.S. Patent 5, 764, 142) . • Degraded mode — in the unlikely event that the CPU-320 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU-320 NAC circuits and Page 2 of 6 — DN-7112: D1 • 10/ 06/ 2009 alarm relay. Each of the four built-in panel circuits includes a Disable/ Enable switch for this feature. • Multi-detector algorithm involves nearby detectors in alarm decision ( U.S. Patent 5, 627, 515) . • Automatic detector sensitivity testing ( NFPA-72 compliant) . • Maintenance alert ( two levels) . • Self-optimizing pre-alarm. FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR • Detects all four major elements of a fire ( smoke, heat, CO, and flame) . • Automatic drift compensation of smoke sensor and CO cell. • High nuisance-alarm immunity. • Six sensitivity levels. FSL-751 VIEW ( VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY: • Revolutionary spot laser design. • Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals ( U.S. Patent 5, 831, 524) . • Addressable operation pinpoints the fire location. • No moving parts to fail or filters to change. • Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost. FAPT-851 ACCLIMATE PLUS LOW-PROFILE INTELLIGENT MULTI-SENSOR: • Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based technology; combination photo and thermal technology. • FlashScan or classic mode compatible. • Low-temperature warning signal at 40° F ± 5° F ( 4.44° C ± 2.77° C) . RELEASING FEATURES: • Ten independent hazards. • Sophisticated cross-zone ( three options) . • Delay timer and Discharge timers ( adjustable) . • Abort ( four options) . • Low-pressure CO2 listed. HIGH-EFFICIENCY OFFLINE SWITCHING 3.0 AMP POWER SUPPLY ( 6.0 A IN ALARM) : • 120 VAC ( NFS-320/ NFS-320C) ; 240 VAC ( NFS-320E) . • Displays battery current/ voltage on panel ( with display) . VOICE FEATURES: • Integrates with FireVoice-25/ 50 Series ( see DN-7004) . • Integrates via serial connection with FireVoice-25/ 50ZS Series ( see DN-7003) .

Tampilkan Lebih Banyak
Kontak Kami  
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus [email protected] !