Kami adalah perusahaan spesialis di bidang System Pemadam Kebakaran, Alarm kebakaran, alarm keamanan, CCTV, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll Fire Protection System : Fire Alarm ( Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll)

Detail Hochiki Fire Alarm Panel, Type : FireNET ( 9th Edition)

Hochiki FireNET ( 9th Edition) Analog Addressable Fire Alarm Control Panel STANDARD FEATURES • UL 864 9th edition approved • Analog design using Hochiki ' s advanced DCP protocol for fast and robust communication • Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop • Uses standard wire, no shielded or twisted pair required on SLC loops • Supports Class B ( style 4) and Class A ( style 6 or 7) SLC loops • 4 on board Class B ( style Y) NAC circuits rated at 2.5 Amp each • Programmable sensitivity levels per device & automatic day/ night sensitivity modes • Automatic daily calibration & drift compensation routine • Large 8-line x 40-character LCD display ( 320 char.) • 2 or 4 loop versions ( 800 addresses/ sub-addr. max.) • Dual RS-485 bus for panel network • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface • 5 on board programmable Form C relays rated at 1 amp at 30VDC ( Fire1, Fire2, trouble, supervisory, aux.) • 500mA of auxiliary power available rated at 24 VDC • Loop Explorer Windows® configuration utility • * 500 network wide software zones • Network Capability of up to 64 panels • RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 16 FN-4127-IO boards • Auto-learn feature • Built in help and alarm information screens • Fire Drill test function • Walk Test function • Alarm Verification feature • FireNET is UL listed for Central Station Service when used with the Bosch D9068 contact dialer • Powerful & versatile Cause & Effect programming ( up to 500 maximum, network wide) including: * Cause & Effect action, * Disable function configuration, * Test mode configuration

Tampilkan Lebih Banyak
metrotama modern
metrotama modern

METROTAMA MODERN

PREMIUM GOLD 5 Tahun
Griya Kebraon Selatan V/E-20, Karangpilang Surabaya
Jawa Timur , Indonesia, SURABAYA
Indonesia 60222
SURABAYA
15 / 10 / 2019
Hubungi Kami

Detail Hochiki Fire Alarm Panel, Type : FireNET ( 9th Edition)

Hochiki FireNET ( 9th Edition) Analog Addressable Fire Alarm Control Panel STANDARD FEATURES • UL 864 9th edition approved • Analog design using Hochiki ' s advanced DCP protocol for fast and robust communication • Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop • Uses standard wire, no shielded or twisted pair required on SLC loops • Supports Class B ( style 4) and Class A ( style 6 or 7) SLC loops • 4 on board Class B ( style Y) NAC circuits rated at 2.5 Amp each • Programmable sensitivity levels per device & automatic day/ night sensitivity modes • Automatic daily calibration & drift compensation routine • Large 8-line x 40-character LCD display ( 320 char.) • 2 or 4 loop versions ( 800 addresses/ sub-addr. max.) • Dual RS-485 bus for panel network • 2 built-in RS-232 interfaces for programming via a PC and serial printer interface • 5 on board programmable Form C relays rated at 1 amp at 30VDC ( Fire1, Fire2, trouble, supervisory, aux.) • 500mA of auxiliary power available rated at 24 VDC • Loop Explorer Windows® configuration utility • * 500 network wide software zones • Network Capability of up to 64 panels • RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 16 FN-4127-IO boards • Auto-learn feature • Built in help and alarm information screens • Fire Drill test function • Walk Test function • Alarm Verification feature • FireNET is UL listed for Central Station Service when used with the Bosch D9068 contact dialer • Powerful & versatile Cause & Effect programming ( up to 500 maximum, network wide) including: * Cause & Effect action, * Disable function configuration, * Test mode configuration

Tampilkan Lebih Banyak