DCP-CZM CONVENTIONAL ZONE MODULE - HOCHIKI

Update Terakhir
:
07 / 08 / 2018
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Kami adalah perusahaan spesialis di bidang System Pemadam Kebakaran, Alarm kebakaran, alarm keamanan, CCTV, Sistem pemadaman api otomatis dengan menggunakan media gas yang ramah lingkungan, dll Fire Protection System : Fire Alarm ( Tyco, Thorn, Notifier, Simplex, Hochiki, GST, Appron, Hooseki, Nohmi, dll)

Detail DCP-CZM CONVENTIONAL ZONE MODULE - HOCHIKI

DCP-CZM CONVENTIONAL ZONE MODULE

HOCHIKI

 

SPECIFICATIONS

Supply Voltage (S-SC) 25.3 ~ 39 VDC

Auxiliary Supply Voltage 18.8 ~ 27.2 VDC

Average Current Consumption

(On S-SC Line) 670μA

2-Wire Detector Loop Current

Standby Detector Load 1mA Max.

From Auxiliary Supply 60mA Max.

EOL Device 4.7K ohms Resistor

Max. Quantity Per Loop 127

Alarm Threshold Level

Wiring Threshold Level >2.5K ohms &

Open Circuit Threshold Level >10K ohms

Max. 2-Wire Conventional

Detector (Loop Resistance) 50 ohms (total wire length)

Dimensions 4.2”W x 4.7”H x 1.4”D

Operating Temperature 32°F (0°C) ~ 120°F (49°C)

Mounting 4” square electrical box

Relative Humidity 90% RH Non-Condensing

 

STANDARD FEATURES

UL 864 9th Edition Listed

Provides an address point for a zone of up to 25

conventional smoke detectors

Blinks green when polled. Latched on red (controlled

by panel) when activated

Device address can be programmed with a

handheld programmer. Device address- ranges

from 1 to 127

Compatible with Class B and Class A wiring

Auxiliary power source provides power for the zone

of detectors

Compatible with conventional detectors, SLR, SIJ,

SLK, SLV, DCD, DFE and SIH series

Tampilkan Lebih Banyak
metrotama modern
metrotama modern

METROTAMA MODERN

PREMIUM GOLD 5 Tahun
Griya Kebraon Selatan V/E-20, Karangpilang Surabaya
Jawa Timur , Indonesia, SURABAYA
Indonesia 60222
SURABAYA
15 / 10 / 2019
Hubungi Kami

Detail DCP-CZM CONVENTIONAL ZONE MODULE - HOCHIKI

DCP-CZM CONVENTIONAL ZONE MODULE

HOCHIKI

 

SPECIFICATIONS

Supply Voltage (S-SC) 25.3 ~ 39 VDC

Auxiliary Supply Voltage 18.8 ~ 27.2 VDC

Average Current Consumption

(On S-SC Line) 670μA

2-Wire Detector Loop Current

Standby Detector Load 1mA Max.

From Auxiliary Supply 60mA Max.

EOL Device 4.7K ohms Resistor

Max. Quantity Per Loop 127

Alarm Threshold Level

Wiring Threshold Level >2.5K ohms &

Open Circuit Threshold Level >10K ohms

Max. 2-Wire Conventional

Detector (Loop Resistance) 50 ohms (total wire length)

Dimensions 4.2”W x 4.7”H x 1.4”D

Operating Temperature 32°F (0°C) ~ 120°F (49°C)

Mounting 4” square electrical box

Relative Humidity 90% RH Non-Condensing

 

STANDARD FEATURES

UL 864 9th Edition Listed

Provides an address point for a zone of up to 25

conventional smoke detectors

Blinks green when polled. Latched on red (controlled

by panel) when activated

Device address can be programmed with a

handheld programmer. Device address- ranges

from 1 to 127

Compatible with Class B and Class A wiring

Auxiliary power source provides power for the zone

of detectors

Compatible with conventional detectors, SLR, SIJ,

SLK, SLV, DCD, DFE and SIH series